Words you will meet in these pages, in plain language. The computer terms come first, then the mass spectrometry ones.

Computer terms

Terminal
A window where you type commands. On Windows it is called PowerShell; on macOS and Linux, Terminal.
Command
A line you type into the terminal and run with Enter, such as thyra --version.
Path
The address of a file or folder, such as /Volumes/data/MSI/brain.d on macOS. On Windows, a path starts with a drive letter, such as D:.
Python
The programming language Thyra is written in. You need it installed, but you do not need to write any.
pip
Python's standard installer for packages such as Thyra.
uv
A fast installer for Python programs. It can also fetch the right version of Python for you.
Environment
A separate set of Python packages, so that the packages of one project do not interfere with another's. Tools such as conda and uv create them.
Jupyter notebook
A document that mixes text with Python code you can run piece by piece. The Explore the result in Python page is one.
SpatialData
An open format and Python library for spatial data from biology, such as imaging mass spectrometry. Thyra saves your data in this format.
Zarr
The way SpatialData stores data on disk: a folder of many small files that programs can read a piece at a time. That is why the result is a folder ending in .zarr.
Table (AnnData)
The part of the result that holds the spectra: one row per pixel, one column per m/z bin. AnnData is the name of the Python format for such tables.
scverse
A community of open-source Python tools for single-cell and spatial biology. SpatialData, napari-spatialdata, scanpy and squidpy belong to it.
napari
A free image viewer. With the napari-spatialdata plugin, it opens SpatialData results.
Command-line option
An extra instruction added to a command, starting with --, such as --pixel-size 50.

Mass spectrometry terms

MSI (mass spectrometry imaging)
Recording a mass spectrum at every point of a sample, so that each m/z value can be shown as an image.
m/z
Mass-to-charge ratio, the x-axis of a mass spectrum.
Spectrum
The intensities measured at one pixel, across the m/z range.
Pixel size
The distance between neighbouring measurement points, in micrometres.
TIC (total ion current)
The sum of all intensities in one spectrum. A TIC image shows it for every pixel, and gives a quick overview of the sample.
Ion image
An image of the intensity of one m/z value, or a narrow range around it, across all pixels.
Profile and centroid data
Profile data records the full shape of each peak. Centroid data keeps one point per peak.
Resampling and m/z bins
Instruments record each spectrum at slightly different m/z values. Resampling moves every spectrum onto one shared set of m/z positions, called bins, so that the same column means the same m/z in every pixel.
Region
A separately defined area of an acquisition, for example one tissue section on a slide that holds several.
Optical image
A photo or microscope scan of the slide, taken before the measurement.
Teaching points
Marks that link positions in the optical image to positions of the instrument's stage. Thyra uses them to lay the MSI data over the photo.
imzML
An open file format for imaging mass spectrometry. It comes as two files: an .imzML file that describes the data and an .ibd file that holds the numbers.
Ion mobility (TIMS)
A separation of ions by their size and shape, in addition to m/z. Bruker timsTOF instruments measure it with trapped ion mobility spectrometry (TIMS).
1/K0
The unit of ion mobility on a timsTOF: the inverse reduced mobility, in V s/cm2. Larger ions of the same charge have a larger 1/K0.
Mass-mobility heatmap
A picture of the whole image in two dimensions: m/z against mobility. Two spots at one m/z but at different mobility are two different ions.
CCS (collision cross section)
A size measure of an ion, worked out from its mobility. The mobility table holds it in the column ccs, in square angstroms. Thyra assumes each ion has charge 1.
MS/MS
Tandem mass spectrometry: selected ions are broken into fragments, and the fragments are measured.
Precursor and fragment
In MS/MS, the precursor is the ion the instrument selects. The fragments are the pieces it breaks into.
PASEF and iprm-PASEF
Bruker timsTOF methods that select precursors one after the other as they leave the mobility separation. In imaging, iprm-PASEF fragments the same list of precursors at every pixel.