Resampling

In plain words

Change how Thyra converts explains the shared m/z axis in plain words. This page has every detail.

Mass axis resampling maps every spectrum in a dataset onto one shared m/z axis. It is enabled by default, and by default every parameter is chosen automatically from the acquisition metadata.

This page explains what that automatic choice is, how it is made, and how to override it. For the list of flags alone, see the CLI Reference.


Why resampling exists

An imzML file comes in one of two storage modes:

Mode m/z arrays Consequence
continuous one shared array for the whole dataset pixels are already comparable bin-for-bin
processed a separate array per spectrum pixel 1's column 500 and pixel 2's column 500 are different masses

For processed data -- which includes most centroided vendor exports -- you cannot build a pixel x m/z matrix at all without first agreeing on a common axis. Thyra reports this as needs_resampling, and it is the reason resampling defaults to on rather than off.

Even for continuous data, resampling is often still what you want: it lets you impose a physically sensible bin spacing, restrict the mass range, or match the axis convention of another tool.

To keep the original per-spectrum axes untouched, disable it:

thyra input.imzML output.zarr --no-resample

Note that with --no-resample on processed data, each pixel keeps its own m/z values, and most downstream tools will not be able to treat the table as a matrix of comparable features.


How the automatic choice is made

Three things are decided: the method (how intensity moves onto the new axis), the axis type (how bin widths scale with m/z), and the bin count.

  acquisition metadata
          │
          ▼
  DataCharacteristics        storage mode, spectrum type, instrument
          │                  name/type/manufacturer, peak density
          ▼
  InstrumentDetectorChain    first matching detector wins
          │
          ├──────────────► resampling method   (nearest_neighbor | tic_preserving)
          ├──────────────► axis type           (constant | *_tof | orbitrap | fticr)
          └──────────────► bin count           from a target width at a reference m/z

What Thyra looks at

DataCharacteristics collects, from the metadata:

  • whether there is a shared mass axis (continuous) or not (processed)
  • spectrum type -- centroid spectrum (MS:1000127) or profile spectrum (MS:1000128)
  • instrument name, instrument type, and manufacturer
  • average peaks per spectrum; above 5000 the data is recorded as high-density profile
  • format flags for Rapiflex, timsTOF, PHI, and Waters

Spectrum type is whatever the file declares -- MS:1000127 or MS:1000128 -- read from the file description first and then from the rest of the document. Only when a file declares neither does Thyra fall back to guessing centroid from processed storage mode, and it says so in a warning when it does. Processed and centroid are independent: processed means each spectrum carries its own m/z array, which says nothing about whether its peaks are centroided.

Peak density is reported but does not select a method or an axis type. It describes how finely the spectra were sampled, not what acquired them, and a dense profile spectrum can come from a MALDI-TOF, a TOF-SIMS, or an Orbitrap run in profile mode.

The timsTOF flag is a case-insensitive substring match on the instrument name, because Bruker names the family many ways (timsTOF fleX MALDI-2, timsTOF Pro 2, timsTOF SCP, and so on). The name comes from the Bruker .d's GlobalMetadata when there is one, and otherwise from the instrument model the imzML itself declares -- so a timsTOF exported to imzML rides the same match, as long as the export names the instrument (see the info box below for the one common exporter that does not).

Which detector wins

Detectors are tried in a fixed priority order and the first match wins: timsTOF, Rapiflex, FT-ICR, Orbitrap, PHI, Waters, generic centroid, then a catch-all default. This table is the actual observed behaviour of that chain:

Metadata Detector Method Axis type
timsTOF, centroid timsTOF nearest_neighbor reflector_tof
timsTOF, profile high-density timsTOF nearest_neighbor reflector_tof
Rapiflex, profile Rapiflex MALDI-TOF tic_preserving constant
Bruker MALDI-TOF Rapiflex MALDI-TOF tic_preserving constant
imzML or mzPeak declaring an FT-ICR analyzer or model FT-ICR nearest_neighbor fticr
solariX .d (native, peaks.sqlite) FT-ICR nearest_neighbor fticr
imzML or mzPeak declaring an Orbitrap analyzer or model Orbitrap nearest_neighbor orbitrap
PHI SmartSoft-TOF .raw PHI SmartSoft-TOF (ToF-SIMS) nearest_neighbor tof
Waters MassLynx .raw, profile trace (the SELECT SERIES MRT default) Waters MassLynx (profile trace) tic_preserving linear_tof
Waters MassLynx .raw, SELECT SERIES MRT vendor centroid Waters SELECT SERIES MRT (vendor centroid) nearest_neighbor tof
Waters MassLynx .raw, vendor centroid or undeclared, other instruments Waters MassLynx nearest_neighbor reflector_tof
unknown vendor, profile (any density) Unknown (default) nearest_neighbor constant
unknown, centroid Centroid, instrument unknown nearest_neighbor reflector_tof
no usable metadata Unknown (default) nearest_neighbor constant

Why PHI needs its own row

Without it PHI reaches the catch-all default and is reported as constant. Thyra's own answer would still be nearest_neighbor, so nothing breaks inside Thyra -- but preview_msi hands that axis type to callers, and a caller that maps constant to profile-MALDI conventions arrives at tic_preserving onto an equidistant axis. That combination is destructive here: a PHI pixel holds a median of 44 measured points across m/z 0.5--1850, and interpolating between them fabricates intensity in every bin in the gaps, with the TIC rescale hiding it behind a total that still balances.

Why PHI's target axis is tof and its source law is linear_tof

These are two different laws on this instrument, and the row above is the target axis. PhiMassAxis steps at a constant flight time, so its channels are spaced as sqrt(m/z) -- that is linear_tof, and it is what source_grid_law reports. The peaks do not follow that law: measured resolving power climbs from about 2,200 at m/z 10 and levels off near 4,250 above m/z 60, where linear_tof would have it climbing as sqrt(m) without end and reflector_tof would have it flat from the start. Only the peak width has any business setting a bin width, so the target axis takes the two-term law fitted to it.

The generic linear_tof default of 17 mDa at m/z 300 would put 42% of the measured peaks under two bins per peak width. The measurements behind this choice, against the instrument's own peak-image export, are in Design Decisions.

Resampling stays on by default for PHI

It is reasonable to ask whether PHI should default to --no-resample, since the native channel grid is the instrument's own measurement and nothing is interpolated either way. On the tuned axis it should not: the resampled store is 22% smaller, has 8.4x fewer columns, opens about 1.8x faster (0.61 s against 1.08 s, medians of four alternating warm reads), and comes out better correlated with the vendor's peak images than the unresampled one. Its remaining recovery spread is window-edge quantisation -- the vendor's windows span 3 to 10 bins, and their edges fall mid-bin -- not lost peak shape; the windows with the fewest bins are exactly the ones with the worst recovery. Use --no-resample when you need var["tof_us"] or the raw channel grid.

tic_preserving is gated on the source and target axis laws matching

A detector may only ask for tic_preserving if it knows the spacing law of the grid the spectra arrive on, and that law is the one it is asking the target axis to use. Two routes qualify. RapiflexReader lays every spectrum out with np.linspace, so the source is uniform in m/z, and the axis it requests is constant -- the same law. The Waters profile trace is the digitiser's own record, sampled at a fixed clock rate and so spaced as sqrt(m/z) (measured (m/z)^0.494 on a SELECT SERIES MRT and (m/z)^0.498 on a Synapt G2-Si), and the axis it requests is linear_tof -- again the same law.

Anything else is refused and gets nearest_neighbor instead, with a log line saying so. The gate is there because Thyra's interpolate-then-rescale operator is exact only when the two laws match -- see the !!! danger box below for what it costs off the diagonal.

How an imzML reaches the Orbitrap and FT-ICR rows

Both detectors match on an instrument_type of "Orbitrap" or "FT-ICR", which the imzML metadata extractor resolves from the file's own instrumentConfiguration, in declaration-strength order: the <analyzer> component cvParam (MS:1000484 orbitrap, MS:1000079 FT-ICR) first, then a recognised instrument-model term (the solariX, apex, LTQ FT, and Orbitrap/Exactive/Exploris families), then a family-identifying product name in free-form model text. A file that declares none of the three stays untyped and falls through to the generic rows below -- an unstated analyzer stays unstated.

The native solariX .d route needs none of this: its extractor stamps instrument_type = "FT-ICR" directly from the instrument identity in peaks.sqlite, so the same FT-ICR row is reached without an export step (see Supported Formats).

One known gap: SCiLS Lab-lineage imzML exports of timsTOF data stamp the generic MS:1001534 Bruker Daltonics flex series term rather than a timsTOF model term. That term genuinely covers the axial flex series too, so Thyra does not attribute it to a timsTOF; a centroid export still lands on the right pair via the centroid row, but a profile export falls to the default. --mass-axis-type remains the explicit override for files whose metadata is silent or too generic.

tic_preserving is selected for profile MALDI-TOF, not for high resolution

It is easy to assume the high-resolution analysers get the more elaborate method. They do not. tic_preserving is chosen for profile data, where a peak is spread over many points and rebinning would otherwise change the total ion count. Orbitrap and FT-ICR data is normally centroided, so it gets nearest_neighbor, which is the correct choice for discrete peaks. Keep nearest_neighbor for profile Orbitrap or FT-ICR data too: Thyra cannot tell whether an imzML's points follow the analyser's own spacing law, and tic_preserving onto the orbitrap or fticr axis of a source that does not follow it distorts intensity ratios by 7x or more (see the box below).

Do not combine tic_preserving with an axis your data does not follow

tic_preserving interpolates onto the target axis and then applies a single scaling factor to the whole spectrum. That is exact only when the target axis is spaced the way the source's own points are. Otherwise a single factor cannot account for bin widths that vary across the mass range differently from the source spacing. On a source sampled evenly in m/z, pairing it with linear_tof, reflector_tof, orbitrap or fticr suppresses high-m/z ions relative to low-m/z ones: across 300-1100 m/z, two ions of equal abundance come back with their ratio distorted by 1.9x on linear_tof, 3.7x on reflector_tof, 7.0x on orbitrap and 13.4x on fticr -- the ratio of the bin widths at the two masses.

Auto-selection cannot produce these pairings. tic_preserving is only ever chosen alongside an axis whose law the source grid itself follows -- constant for the Rapiflex, linear_tof for the Waters profile trace -- which is what makes it exact; the detector chain enforces that, and it re-checks once the axis is settled, so overriding the axis with --mass-axis-type downgrades an auto-selected tic_preserving to nearest_neighbor rather than interpolating onto an axis the source does not follow.

You therefore have to ask for a mismatched combination explicitly, by naming --resample-method tic_preserving yourself, and Thyra takes you at your word -- with a warning when it contradicts the detector.

If your data does not follow the axis you want, use nearest_neighbor, which moves each peak into a single bin and is unaffected by bin width.

The chosen detector, method, and axis type are all logged:

INFO - Detected instrument type: timsTOF
INFO - Selected resampling method: NEAREST_NEIGHBOR
INFO - Selected axis type: REFLECTOR_TOF

Overriding the detector

--resample-method overrules the detector, and the detector is still asked what it would have picked. When the two disagree, the conversion says so and carries on:

WARNING - Resampling method TIC_PRESERVING was given explicitly, but this
source's detector chose NEAREST_NEIGHBOR for it. Interpolating a source the
detector reads as sparse fills the whole axis: [...] Pass
--resample-gap-tolerance to discard bins no measured m/z vouches for, or drop
the override.

Nothing about the output changes -- the method you asked for is the method used. The warning exists because the failure it points at is invisible in the totals: on a 713-frame PASEF acquisition, --resample-method tic_preserving stored 423,386,757 non-zeros against 302,106 for the detector's choice, a 583 MB table against 7.6 MB, and per-pixel TIC identical to the last digit. Adding --resample-gap-tolerance 0.01 to the same command brings it down to 4,801,946. See Gaps in the source m/z values.


Methods

nearest_neighbor

Each target bin takes the intensity of the nearest original m/z value. Peaks stay sharp and stay put, and no intensity is invented between them. This is the right choice for centroid data, where a peak is a single discrete mass and smearing it across neighbouring bins would be wrong. The operator is NearestNeighborStrategy in thyra.resampling.strategies.

The bin a peak lands in is computed, not searched for: every axis type is laid uniformly in one analytic coordinate (m/z itself, sqrt, ln, 1/sqrt, 1/m, or the tof law's own cumulative), so the nearest bin is the peak's position in that coordinate rounded, checked against its two neighbours. It is the same bin the binary search found, for every peak -- design decision D21 has the argument and the measurements -- and a quarter to a half of the conversion time less on a centroid dataset of a few thousand peaks per spectrum.

Consequence worth knowing: on a target axis finer than the source spacing, most bins receive nothing. A dataset resampled from 4,000 source points onto 190,000 bins has exactly 4,000 populated bins per spectrum, and the rest are zero. This is why you should extract ion images by summing over an m/z window rather than picking the single nearest bin -- see the tutorial.

tic_preserving

Linear interpolation onto the target axis, followed by rescaling so the spectrum's total ion current matches the original. This is the right choice for profile data: a peak spans many points, interpolation reconstructs its shape on the new grid, and the rescaling step stops rebinning from quietly changing quantitation. The operator is TICPreservingStrategy in thyra.resampling.strategies.

Use it whenever the total ion count per pixel has to stay comparable before and after conversion.

Interpolating at a bin's centre reads only the two source samples either side of it. Once bins are wide enough that one holds a sample neither of those is, that sample's ion current would be lost. Such a spectrum is rebinned instead, wherever a bin holds two or more samples: each sample stands for the stretch of m/z halfway to its neighbours, and every bin takes the share of that stretch it overlaps. A peak narrower than a bin then keeps its ion current wherever it falls. The spectrum's other bins are scaled by bin width over sample spacing, so both kinds of bin count ions on one scale. On an evenly sampled source this starts at about two bins per sample; below that, spectra are resampled by interpolation alone, as described above. See D50 for the measurements.

The total that is preserved is the share of the spectrum inside the axis range. If you crop with --resample-min-mz or --resample-max-mz, intensity outside the window is dropped rather than redistributed over the bins you kept, so the per-pixel total falls by whatever you cropped out -- a cropped window should not claim ions from the parts that were cut away. That share is measured by area, so a window narrower than the spacing between source points still keeps a proportionate amount instead of collapsing to zero.

With the default axis, which spans the dataset's own mass range, nothing is dropped and the total is preserved exactly.

Gaps in the source m/z values

Interpolation has no notion of a gap. Between the last source point before an empty stretch and the first one after it, np.interp draws a straight line, and every target bin in between gets an intensity that was never measured. On sparse or thresholded m/z arrays that is most of the axis: forcing tic_preserving onto bellini.imzML -- 2,222 points per spectrum, median source spacing 0.0072 Da, largest gap 1,269 Da -- puts 80.6% of the output total ion current more than 0.5 Da from any measured point.

--resample-gap-tolerance sets how far a target bin may sit from the nearest source m/z before its interpolated value is discarded instead of trusted. It is the same parameter Cardinal calls tolerance and matter calls tol.

thyra data.imzML out.zarr \
  --resample-method tic_preserving \
  --resample-gap-tolerance 0.1

Masking happens before the TIC rescale, so the intensity returns to the bins that do have measurements behind them rather than being deleted; the per-pixel total is still preserved. A rebinned bin holds measured samples, and the tolerance never removes it.

Sizing it: on a source grid of uniform step s, no target bin is ever more than s/2 from a source point, so any tolerance above half the widest gap in your source m/z values changes nothing. Continuous profile data is dense and evenly sampled, which is why the default is no limit -- there is nothing to refuse. Set it when your m/z arrays are sparse or peak-picked and you are asking for tic_preserving anyway.

nearest_neighbor needs no such parameter: it only ever fills a bin some peak was snapped into.


What "in range" means

Both methods keep a peak when it lies inside the declared mass range -- --resample-min-mz and --resample-max-mz, or the source's own range when you set neither. Peaks outside it are discarded, not folded into the first or last bin.

The declared range is not quite the same as the span of the axis points. Every physics axis type lays its bins as target_bins + 1 edges across the range and stores the centres, so the first and last centre sit half a bin inside the range you asked for: a source declaring 50-1000 m/z builds an axis running 50.0001 to 999.9975. A peak at exactly 50.0 still belongs in the first bin, and Thyra keeps it there. That matters most for sources whose declared range is their first and last sample: PHI ToF-SIMS takes its mass range from the first and last detector channel, so dropping boundary peaks would lose both channels in every pixel.

constant axes are unaffected either way: they are laid out with np.linspace(min_mz, max_mz, n), whose end points already are the declared bounds. --no-resample is unaffected too -- the axis there is the source's own values.

The mass-mobility heatmap, the mobility table and the MS/MS table keep the same range, so they hold the same edge peaks as the summed table.

Dropping is deliberate and is reported once per conversion:

WARNING - Dropping peaks that fall outside the target mass range
[250.0000, 1200.0000] m/z -- 2 of 20 in the first spectrum affected. They are
discarded, not folded into the edge bins. Widen the resampling range to keep
them.

Folding them in instead would be worse: clamping every out-of-range peak onto the nearest edge bin puts 654,158 counts in bin 0 of pea.imzML cropped to 400-800 m/z, where a real peak there is around 80. The total is conserved exactly, so no TIC check would see it.


Axis types

The axis type sets how bin width grows with m/z. Each corresponds to the physics of a mass analyser, so that bins track the instrument's real resolving power instead of over-sampling the low end and under-sampling the high end.

Axis type Name in SCiLS Lab Bin width scales as Rationale
constant Constant (equidistant) constant Da Equidistant bins
linear_tof Axial TOF sqrt(m/z) Linear TOF: flight time t ∝ sqrt(m/z), so equal time bins give sqrt(m/z) mass bins
reflector_tof Orthogonal TOF m/z Constant relative resolution R = m/Δm; bins are uniform in ln(m/z)
tof -- sqrt(A m + B m^2) A measured TOF peak width; linear_tof and reflector_tof are its two limits. See The two-term TOF law
orbitrap Orbitrap m/z^1.5 Orbitrap frequency f ∝ 1/sqrt(m/z), so equal frequency bins give m/z^1.5 mass bins
fticr MRMS (Fourier-transform) m/z^2 Cyclotron frequency f ∝ 1/(m/z), so equal frequency bins give m/z^2 mass bins

SCiLS Lab offers the same five laws for its common mass axis, under the names in the second column, so an axis can be matched between the two. Its earlier versions called linear_tof and reflector_tof "Linear TOF" and "Reflector TOF".

reflector_tof is the most broadly useful of these: constant relative resolution means constant relative mass accuracy across the whole range, which is what most MS workflows assume.

The two-term TOF law

A time-of-flight peak's width in flight time has a constant part (detector and digitiser response, pusher timing) and a part proportional to the flight time (energy spread, turnaround time), added in quadrature. In m/z:

FWHM(m) = sqrt(A * m + B * m^2)        m in Da, FWHM in mDa

A is in mDa2/Da and B is dimensionless. linear_tof is the B = 0 limit (width grows as sqrt(m)), reflector_tof the A = 0 limit (width grows as m, constant ppm, with 1/sqrt(B) the resolving power). Real instruments sit between, and where they sit is measurable from a few hundred isolated peaks by least squares on FWHM^2 = A m + B m^2:

Instrument A B 1/sqrt(B) Fitted from
SELECT SERIES MRT 0.0185 9.1e-6 331,000 229 peaks, m/z 300-1000 (R2 0.36 on FWHM2: the peaks scatter, the trend does not)
timsTOF fleX 0.0877 8.74e-4 34,000 180 peaks, m/z 300-1000 (R2 0.89)
PHI nanoTOF 0.454 0.0284 5,900 311 peaks, m/z 12-377, across 12 acquisitions (2017-2026, both polarities) -- quantile regression at q = 0.05, not least squares

The MRT pair reproduces the measured 2.97 / 3.79 / 4.54 mDa at m/z 400 / 600 / 800; a log-log fit of the same peaks gives an exponent of 0.67, between the 0.5 and 1.0 the two single-term laws allow, which is why neither of them fits an MRT centroid list exactly. The timsTOF pair is within 10% of the reflector_tof shape over m/z 400-1000 (7% at 400, 3% at 600; the constant term shows below that and the gap reaches 10% at m/z 300), so nothing changes for timsTOF by default and the pair is opt-in.

The nanoTOF pair is fitted differently, and the difference is worth understanding if you fit a law for an instrument of your own. Least squares runs the law through the middle of a corpus, so half of every acquisition's peaks come out narrower than it predicts and get fewer bins than intended -- on this corpus, 12% of peaks would have landed under two bins per peak width. The two errors are not symmetric: a peak broader than the law simply gets more bins than it needs, costing store and nothing else, while a peak narrower than the law is the one case that loses shape. So the fit is placed at the narrow edge instead -- quantile regression at q = 0.05 on FWHM^2 = A m + B m^2, which puts 94% of the 311 measured peaks at three bins per width or better and none below two. It costs 20% more bins than a least-squares fit of the same data, and buys a 6% failure rate instead of 70%. ToF-SIMS resolving power varies by a factor of three between tunes, and a C60 primary beam resolves about five times worse again (R 280-1,200 against 1,700-7,100 for Bi3); those acquisitions are deliberately oversampled by this law rather than averaged into it.

The axis lays bins at FWHM(m) / k for k bins per peak width (default 3). The cumulative bin count has a closed form, (2/sqrt(B)) asinh(sqrt(B m / A)), so the axis is a uniform grid in that variable and the count is exact.

# An MRT centroid conversion: this is the default, no flags needed
thyra mrt_run.raw out.zarr --waters-spectrum centroid

# A timsTOF opting in to its measured pair (the default stays reflector_tof)
thyra run.d out.zarr --mass-axis-type tof

# A TOF instrument Thyra has no pair for, fitted from its own peaks
thyra run.imzML out.zarr --mass-axis-type tof --tof-law 0.0185 9.1e-6

# Finer bins: the width at the reference m/z sets k, as on any other axis
thyra run.d out.zarr --mass-axis-type tof \
    --resample-width-at-mz 0.005 --resample-reference-mz 1000

--mass-axis-type tof takes the pair the detected instrument declares (MRT centroid, timsTOF, PHI nanoTOF); --tof-law A B supplies one for an instrument that has none, and it is an error to have neither. There is no separate flag for the bins per peak width: --resample-width-at-mz at --resample-reference-mz fixes it, since k is whatever puts a bin of that width at the reference m/z. The Python API's ResamplingConfig also accepts bins_per_fwhm directly, on a tof axis only and never beside a width or a bin count: either of those fixes the bin count too, so the pair is refused.

Centroid axes follow peak width; profile axes follow the sample grid. The law describes how wide a peak is, which is what the bins of a centroid list should track. A profile trace is a set of samples on the digitiser's own grid, and its bins should track that grid instead -- the Waters profile default uses linear_tof because that is how its samples are spaced (see Supported Formats), not because of how wide its peaks are. The two-term law is never applied to profile data, nor to FT-ICR or Orbitrap data, whose widths are not time-of-flight quantities.


Bin count

You can set the bin count directly, or specify a target bin width at a reference m/z and let Thyra derive the count from the axis physics. The two are mutually exclusive.

When you specify neither, the detected instrument may declare a width; failing that, the axis type's default applies:

Source Default width At reference m/z
Waters SELECT SERIES MRT vendor centroid tof law at 3 bins per FWHM (1.75 mDa) 1000
Waters vendor centroid, other instruments 2 mDa 1000
Waters SELECT SERIES MRT profile trace 1.3 mDa 1000
Waters profile trace, other instruments 1.14 x the run's predicted sample spacing 1000
PHI SmartSoft-TOF (ToF-SIMS) tof law at 3 bins per FWHM (about 57 mDa) 1000
any other source, linear_tof 17 mDa 300
any other source, everything else 5 mDa 1000

The Waters figures are measured, not conventional. 2 mDa is the coarsest centroid setting that clears two bins per measured peak width at m/z 800 on an MRT (2.8 bins per FWHM of 4.48 mDa; the earlier 5 mDa gave 1.1). 1.3 mDa is about 1.14 times the MRT digitiser's sample spacing at m/z 1000, pinned rather than derived so every MRT run with the same mass range shares one axis; see Supported Formats. An instrument's width applies only on the fully automatic path -- set --mass-axis-type and the width defaults revert to the axis type's, since a width tuned for one law is not a sensible default for another.

The 17 mDa / m/z 300 pairing for linear_tof is a working default, close to the axis SCiLS Lab produces for FlexImaging data but not a claim of exact equivalence. To match a particular SCiLS project, set --resample-width-at-mz and --resample-reference-mz from that project's own axis.

The count is then derived per axis type:

Axis type Bin count
reflector_tof ln(max/min) * (ref_mz / width)
linear_tof (2/k) * (sqrt(max) - sqrt(min)), k = width / sqrt(ref_mz)
orbitrap 2 * (1/sqrt(min) - 1/sqrt(max)) * (ref_mz^1.5 / width)
fticr (1/min - 1/max) * (ref_mz^2 / width)
constant (max - min) / width

Each is the integral of 1 / width(m) across the mass range, so the bin width the axis actually realizes at your reference m/z is the width you asked for. A count derived this way is floored at 100 bins; a count given with --resample-bins is used as it is. When the floor or a given count sets the axis, its bins are not the width asked for, and the stored resampling step records the width (and, on a tof axis, the bins per FWHM) the axis has.

A worked example, from the tutorial's synthetic dataset -- 250-1200 Da, constant axis, default 5 mDa width:

(1200 - 250) / 0.005 = 190000 bins

which is what the log reports:

INFO - Calculating bins for 5.0 mDa width at m/z 1000.0
INFO - Calculated 190000 bins for constant axis type
INFO - Building resampled mass axis: 250.00 - 1200.00 m/z, 190000 bins

190,000 bins from 4,000 source points sounds extravagant, and on the nearest_neighbor path -- which is what auto picks for this dataset -- it very nearly is free. Each source point lands in exactly one bin, so the non-zero count does not depend on the bin width at all and only the index arrays lengthen: the tutorial store comes out at roughly 31 MB, and going from 4,000 bins to 190,000 costs about +0.8% on disk.

That only holds for nearest_neighbor, and for zero-suppressed profiles

tic_preserving interpolates, so on a continuous profile it populates essentially every bin. The matrix comes out 99.998% dense and the store becomes n_pixels x target_bins x ~7.5 bytes -- independent of how sparse the source was. Measured on this same 4,000-point source: at 190,000 bins it costs 1.44 MB per pixel, so 400 pixels take 574 MB against 6.93 MB at 4,000 bins, an 82.9x blowup, and the 1,728-pixel tutorial dataset would take roughly 2.5 GB.

The exception is a source that stores explicit zeros around its peaks and nothing in between, like the Waters profile trace. Interpolation between two zeros is zero, so only the bins under the stored clusters are populated -- and only those are evaluated, which is what keeps the MRT default's conversion time in line with nearest-neighbour binning.

On that path the default bin count is a decision rather than a detail.

Pass --resample-bins or --no-resample if you would rather not upsample.

The 10 million bin cap

--no-resample on a processed-mode imzML does not build a physics axis at all. It builds the raw axis: every distinct m/z value in the whole dataset, one column each. When the peak lists genuinely share m/z values that is small. When they do not -- which is the normal case for centroided peak picking, where two pixels almost never report a peak at the same double -- it grows to roughly one column per peak in the entire dataset, and there is no natural stopping point.

Thyra gives up once that axis passes 10 million unique m/z values, and says what to do instead:

Common mass axis exceeded 10,000,000 unique m/z values after
12,400 of 918,855 spectra (10,004,112 so far). The peak lists in this dataset
do not share m/z values, so a raw axis grows to roughly one column per peak,
which is not usable downstream. Convert with resampling instead (it is the
default; --no-resample disables it), or raise max_mass_axis_length.

10 million bins is also the limit SCiLS Lab sets on its common mass axis, so a store within the cap stays within what that software can load.

The cap is Python-API only, through reader_options, and applies to the imzML reader:

from thyra import convert_msi

convert_msi(
    "data.imzML",
    "out.zarr",
    reader_options={"max_mass_axis_length": 50_000_000},  # or None for no cap
)

It has no effect when resampling is on, which is the default: a resampled axis has the bin count you asked for.

The value is a count, so it must be a positive integer or None. Anything else is refused before the file is opened.


Overriding the automatic choice

Every part is independently overridable; anything you leave alone stays automatic.

# Method and axis type. nearest_neighbor is the pairing to use with an
# axis your data does not follow -- see the danger box under
# "Which detector wins" above.
thyra input.imzML output.zarr \
    --resample-method nearest_neighbor \
    --mass-axis-type orbitrap

# Fixed bin count
thyra input.imzML output.zarr --resample-bins 50000

# Target width at a reference m/z instead of a bin count
thyra input.imzML output.zarr \
    --resample-width-at-mz 0.01 \
    --resample-reference-mz 500

# Restrict the mass range
thyra input.imzML output.zarr \
    --resample-min-mz 400 --resample-max-mz 1000

# Off entirely
thyra input.imzML output.zarr --no-resample
from thyra import convert_msi

convert_msi(
    "input.imzML",
    "output.zarr",
    resampling_config={
        "method": "nearest_neighbor",
        "axis_type": "orbitrap",
        "width_at_mz": 0.01,
        "reference_mz": 500.0,
    },
)

The Python API does not resample by default

convert_msi() called without resampling_config keeps the original mass axis, whereas the thyra command-line tool resamples by default. Pass a resampling_config explicitly if you want the CLI's behaviour from Python.


One axis for several data sets

To compare data sets bin for bin, they need the same mass axis. Plan the axis once, then give the plan to every conversion.

from thyra import convert_msi, plan_mass_axis

plan = plan_mass_axis(["a.imzML", "b.imzML"])
print(plan.origins)    # where each setting came from
print(plan.warnings)   # what the plan costs each source
plan.save("axis.json")

convert_msi("a.imzML", "a.zarr", resampling_config=plan)
convert_msi("b.imzML", "b.zarr", resampling_config=plan)

On the command line, pass the saved file: --mass-axis-plan axis.json. The plan fixes the axis, so the other axis options cannot be combined with it.

The plan takes the range all sources share and, on most axes, the widest bin width any source declares. Each source keeps its own resampling method. A conversion refuses to run when the axis it builds is not the planned one. An imzML range is moved out by the last digit its header states, because the header rounds it. Pass axis_type, min_mz, max_mz or width_at_mz to set a value yourself.


Checking what was used

The decision is recorded in the output store, so a converted dataset is self-describing:

import spatialdata as sd

sdata = sd.read_zarr("output.zarr")
table = sdata.tables["msi_dataset_z0"]

mz = table.var["mz"].values
print(f"{len(mz)} bins, {mz.min():.2f} -- {mz.max():.2f} m/z")

# Bin width across the range tells you the axis type in practice:
# flat -> constant, growing linearly -> reflector_tof, and so on.
import numpy as np
d = np.diff(mz)
print(f"bin width: {d.min()*1000:.3f} -- {d.max()*1000:.3f} mDa")

For the tutorial dataset this prints a flat 5.000 mDa across the range, confirming a constant axis at the default width.


Practical guidance

  • Leave it alone unless you have a reason. The detected settings are right for the common Bruker and imzML cases.
  • Disable it (--no-resample) when you want the untouched vendor axis -- your own peak picking, centroiding, or calibration downstream.
  • Leave the method on auto for profile data too. Thyra picks tic_preserving only where it knows the spectra follow the target axis (Bruker rapifleX and other Bruker MALDI-TOF data, and the Waters profile trace); anywhere else interpolation would distort intensity ratios, as the danger box above measures.
  • Set --resample-bins any time you need to match another tool's axis exactly.
  • Narrow the mass range (--resample-min-mz / --resample-max-mz) before increasing bin counts; it is usually the cheaper way to get the resolution you need where you need it.

See also