Metadata Schema

In plain words

Describe and share your data covers what Thyra records and how to prepare a METASPACE submission, in plain words. This page has every field.

Every store Thyra writes carries a versioned, ontology-mapped metadata block: table.uns["msi_metadata"]. Its base fields mirror the METASPACE submission form, so a converted dataset already holds every answer its source reports; the rest, such as the organism and the matrix, is added when you export (see Completing the metadata).

The schema exists because MSI has had no structured metadata convention the way other spatial omics modalities do. Vendor files spell the same fact many ways, imzML metadata is free-form cvParams, and every pipeline re-invents its own dictionary. This block fixes the names, maps them to ontologies, and ships a validator.

Where this sits in the format stack

Raw/archival exchange is the domain of mzPeak (the HUPO-PSI working draft succeeding mzML); SpatialData is the analysis-ready layer and Thyra's output. Thyra is the bridge between the two, and this schema is the analysis-layer metadata contract: PSI CV-anchored like the raw layer, so nothing is lost crossing the bridge. Raw ragged spectra stay in the raw layer; they are deliberately not part of Thyra's output.

import spatialdata as sd

sdata = sd.read_zarr("output.zarr")
block = sdata.tables["msi_dataset_z0"].uns["msi_metadata"]

print(block["schema_version"])                       # "0.14.0"
print(block["ms_analysis"]["pixel_size_um"])         # {"x": 20.0, "y": 20.0}
print(block["ms_analysis"]["ionisation_source"])     # "MALDI"
print(block["ms_analysis"]["ionisation_source_term"])
# {"accession": "MS:1000075",
#  "name": "matrix-assisted laser desorption ionization"}

The document

Seven sections and a processing list. ms_analysis and provenance are written by the converter for every store; acquisition, calibration and alignment are each written when the reader reports at least one of their facts and are absent otherwise; sample and preparation describe things no raw file records (what the tissue was, how it was prepared) and are supplied by you -- see Completing the metadata. The one exception is the sample's id and name, which a conversion writes when it is given them (convert_msi(sample_id=..., sample_name=...) or --sample-id).

Section Field Type Ontology
(root) schema_version MAJOR.MINOR.PATCH string; thyra validate requires it, the published JSON Schema does not --
sample sample_id text, your identifier for the sample; never read from the source PSI-MS (MS:1000001)
sample_name text, your name for the sample; never read from the source PSI-MS (MS:1000002)
organism, organism_term text + term NCBITaxon
organism_part, organism_part_term text + term UBERON
condition text --
sample_growth_conditions text --
preparation sample_stabilisation text --
tissue_modification text --
matrix, matrix_term text + term CHEBI
matrix_application text --
solvent text --
ms_analysis polarity, polarity_term "positive"/"negative" + term PSI-MS
spectrum_representation, spectrum_representation_term "profile"/"centroid" + term, the representation the reader delivered PSI-MS (MS:1000525; MS:1000128 / MS:1000127)
ionisation_source, ionisation_source_term text + term PSI-MS
analyzer, analyzer_term text + term PSI-MS
instrument_model text --
manufacturer text, the source's own spelling where it states one; set by Thyra for Waters, Rapiflex and PHI, and "Bruker" for a solariX file that does not say PSI-MS (MS:1001269)
serial_number text, identifies one physical machine PSI-MS (MS:1000529)
detector_resolving_power {value, at_mz} --
pixel_size_um {x, y}, required --
n_spectra integer, the spectra the source holds as its reader counted them --
ion_mobility {present, separation, separation_term, unit_term, range_lower, range_upper, num_scans, resolved_table, grid} PSI-MS (MS:1002815 / MS:1002476, unit MS:1002814)
fragmentation {present, ms_level, constant_across_pixels, merges_precursors, dissociation_term, windows, resolved_table} PSI-MS (MS:1000511; windows MS:1000827 / 828 / 829, MS:1000045, MS:1000133)
acquisition acquisition_datetime ISO 8601 YYYY-MM-DDThh:mm:ss[.fff], with a UTC offset only when the source recorded one --
laser_power_percent number, percent of the laser's range --
laser_frequency_hz number, hertz IMS (IMS:1006000)
shots_per_pixel integer, laser shots summed into one pixel's spectrum IMS (IMS:1006001)
method_file text, the acquisition method's file name (never a path) --
calibration calibration_datetime ISO 8601 at the source's precision (YYYY-MM-DDThh:mm[:ss[.fff]]), with a UTC offset only when the source recorded one --
recalibrated boolean, a calibration made after the acquisition replaced the one it ran under --
original_calibration_datetime as calibration_datetime, for the calibration a recalibration replaced --
software, software_version text, what made the calibration, in the source's words --
n_reference_peaks integer, the reference peaks the calibration was fitted to --
mz_standard_deviation_ppm number, their residual in ppm (see below); never zero --
lock_mass_corrected boolean, the m/z values were corrected against a lock mass --
alignment optical_image_file text, the file name of the optical image the raster is registered onto (never a path) IMS (IMS:1006008)
method text, how that image was aligned with the raster, e.g. "teaching points" IMS (IMS:1006017)
teaching_points list of {image_x_px, image_y_px, stage_x_um, stage_y_um}: a pixel of the image and the stage position of the same feature --
processing list of {name, action_term, software {name, version, uri}, parameters} ordered steps, oldest first PSI-MS data processing action (MS:1001485 for m/z calibration)
provenance thyra_version text, required --
source_format "imzml", "bruker", ... --
source_path text, the source's path in a store block and its name alone in a document --
pixel_size_source "automatic" / "manual" / "default" --
mass_axis optional {sha256, n_bins}: a SHA-256 of the store's var["mz"] (little-endian float64 bytes, lower-case hex) and its length; written for every conversion, resampled or not; absent from a document and from stores older than 0.11.0 --

An ontology term is always the pair {"accession": "MS:1000075", "name": "matrix-assisted laser desorption ionization"} -- a CURIE plus the term's label, so the block is readable without resolving anything.

pixel_size_um is the one acquisition field that is required: conversion refuses to run without a pixel size, so a document without it describes no store Thyra ever wrote. It is a pair because a raster need not be square, and the same pair reaches the rest of the store -- the root attrs, the coordinate system and its affine, the element transforms and obs["spatial_x"]/["spatial_y"].

Unknown fields are rejected

Validation refuses keys the schema does not define, so a typo fails loudly instead of becoming an unread field. Anything genuinely vendor-specific already has a home in the sections beside this block (format_specific, acquisition_params, raw_metadata -- see Output Format).

What is auto-populated

Auto-population is deliberately honest: a field the source does not report is left unset, never guessed. The only inferences are facts that follow from the format itself.

Source polarity ionisation source analyzer instrument model
imzML from MS:1000130 / MS:1000129 in fileContent, a parameter group or the spectra, when all agree (MS:1000128 named "positive scan", a known exporter mistake, counts as positive) -- from the <analyzer> component cvParam from the instrumentConfiguration (model term or MS:1000031 value)
mzPeak from file_description.contents and each spectrum's scan_polarity, when all agree -- as for imzML as for imzML
Bruker timsTOF .d from Frames.Polarity, when every frame agrees MALDI, when the laser tables are present TOF from the DB
Bruker solariX .d from the file -- -- from the file
Bruker Rapiflex -- -- -- --
PHI ToF-SIMS from the header SIMS TOF platform name
Waters .raw -- -- -- SELECT SERIES MRT on an MRT, Thyra's own label; otherwise unset

spectrum_representation is the representation the reader delivers, so resampling never changes it:

Source spectrum representation
imzML from the file's declaration (MS:1000127 / MS:1000128), or --spectrum-type
mzPeak centroid when read from the peaks member, profile when the archive fills both members, else the file's declaration
Bruker timsTOF .d centroid for TSF and for TDF read with vendor_centroid; profile for TDF read with scan_sum (the default)
Bruker solariX .d centroid
Bruker Rapiflex, PHI ToF-SIMS profile
Waters .raw what the reader returns (--waters-spectrum)

An imzML that declares neither term leaves the field unset. Thyra still guesses centroid for a processed-mode file, to pick a resampling method, but that guess stays in uns["essential_metadata"]["spectrum_type"].

A timsTOF .d also fills ion_mobility: present: true for a TDF acquisition (TIMS engaged), with the acquired 1/K0 range and the ramp length in scans, and present: false for TSF. An imzML states it as well: present: true with the array's terms when the file declares a mobility array, present: false otherwise. A Waters run with drift bins states present: true with drift time (MS:1002476, ms), its range and the bin count. Other formats, and Waters runs without drift bins, leave the field unset, which means "not reported", not "no mobility". The MSI table is always summed over the ramp; how it was summed is the tdf_spectrum parameter of the conversion processing step (see Supported Formats). resolved_table names the mobility-resolved sibling table when one was written beside the summed table, and grid ({law, lower, upper, n_channels}) describes the common mobility grid such a table was binned onto when it was built from per-pixel mobility values (--mobility-grid); both are unset otherwise. grid is the only thing in the store that says which of the two mechanisms filled that table -- reading it off a shared feature axis bins nothing -- and it is a description, not a structural difference: the table is the same shape either way. The arrays that describe the axis itself and the mass-mobility heatmap live outside this block, in uns["mobility_axis"] and uns["mobility_heatmap"] (see Output Format): this block is versioned and carries no arrays.

Bruker .d also fills fragmentation from Frames.MsMsType and whichever precursor table the acquisition uses -- PasefFrameMsMsInfo for PASEF frames, DiaFrameMsMsWindows for DIA frames (MsMsType 9), FrameMsMsInfo for single-precursor ones -- in a TSF acquisition as well as a TDF one. What stays TDF-only is the demultiplexed sibling table, which needs the mobility scan ranges only PASEF and DIA frames record. present: false records a survey acquisition; the field is left unset when the database cannot be asked at all, which means "not reported", not "MS1". windows is stored as a JSON string (a list of objects does not round-trip through AnnData/zarr) and decoded by read_msi_metadata_blocks and thyra validate. The field names and terms are mzPeak's, so an archive and a store describe a precursor the same way; see Output Format for the array block beside it and for what merges_precursors means for the stored spectrum. Waters .raw fills it too, from the precursor m/z MassLynx reports per scan: a file whose converted functions carry one reports it here, and a file that also holds MS1 functions converts those alone, reports MS1, and lists the MS/MS functions it left out under excluded_functions in the Waters-specific block. The MS level MassLynx reports is not used on its own, because on a raster it split across functions the level is a chunk artefact (see Supported Formats).

The acquisition section is filled the same way, from the vendor values the reader already keeps in uns["acquisition_params"], and only where the value's meaning and unit were checked against an acquisition:

Source acquisition_datetime laser_power_percent laser_frequency_hz shots_per_pixel method_file
Bruker tsf/tdf GlobalMetadata.AcquisitionDateTime, with offset MaldiFrameInfo.LaserPower MaldiFrameInfo.LaserRepRate MaldiFrameInfo.NumLaserShots GlobalMetadata.MethodName, name only
Bruker solariX Properties.AcquisitionDateTime, with offset Spectra.LaserPower Spectra.LaserRepRate Spectra.NumSummations (it equals the method's NumLaserShots) the *.m directory's name
Bruker rapiflex -- (the info file's Start Time format is unverified) -- (unit unverified) -- Number of Shots Method
PHI ToF-SIMS AcqFileDate, no offset -- (ion gun) -- -- --
Waters .raw MassLynx's acquisition date and time, no offset -- -- -- $$ MS Method in _header.txt, name only
imzML -- -- -- -- --

A Bruker per-frame value that varied across the acquisition is reported in acquisition_params as a [min, max] pair and leaves the schema field unset: the section states one value per acquisition or none. A timestamp in a format the builder does not parse stays unset too, with the raw string untouched beside it. No time zone is ever assumed: PHI and Waters record none, so their timestamps carry none. resolved_table names the demultiplexed sibling table when one was written, mirroring ion_mobility.resolved_table, so both kinds of sibling are discoverable from this block alone.

A precursor's m/z here and in var["precursor_mz"] is the isolation window target (MS:1000827) -- the m/z the quadrupole was set to -- and not MS:1000744, a selected ion whose m/z was measured. mzPeak keeps the two in separate files for the same reason; do not read either as a monoisotopic mass.

detector_resolving_power is filled when the source states both the value and the m/z it is quoted at (an extractor reports them as resolving_power and resolving_power_at_mz); one without the other is not written, because a resolving power is not comparable without its reference m/z. No shipped reader states the pair today, so for the formats Thyra converts it is supplied by you like the fields below.

n_spectra is the reader's own count of the spectra the source holds -- the ones present, not the positions the raster covers, and one region's when one was read. It is left unset where the reader did not count (a PHI preview decodes no events, so thyra metadata has no count for PHI), and the table can have fewer rows than it says: a spectrum with nothing in it is not stored.

The calibration section describes how the source's m/z values were calibrated. "The calibration" is the one they rest on: the most recent recalibration when there is one, otherwise the calibration the acquisition ran under. Every field comes from what the vendor states, and only where its meaning was checked against real acquisitions:

Source calibration_datetime recalibrated software, software_version n_reference_peaks, mz_standard_deviation_ppm lock_mass_corrected
Bruker tsf/tdf CalibrationInfo.CalibrationDateTime in the analysis database, with offset; for recalibrated data the latest calibration.sqlite state's time, with the database's as original_calibration_datetime from calibration.sqlite: its first state is written at acquisition, so only a second is a recalibration; unset without the file CalibrationSoftware, CalibrationSoftwareVersion; the latest state's source and version when recalibrated the reference masses with a corrected mass, and MzStandardDeviationPPM; unset for a recalibration, since no recalibrated acquisition was at hand to check what its state records --
PHI ToF-SIMS the appended recalibration's BlockAppendedDate, no offset; unset for the header's calibration, which has no date an appended block with new coefficients -- the calibrants of the calibration in force, from their measured and theoretical m/z --
Waters .raw $$ Cal Date and $$ Cal Time in _header.txt, to the minute, no offset -- -- -- (Cal StdDev is 0 on every file read) MassLynx isLockmassCorrected
imzML, solariX, rapiflex, mzPeak -- -- -- -- --

recalibrated counts states. A .d whose calibration.sqlite was created by a recalibration -- DataAnalysis writes one into a .d that had none -- holds that recalibration as its only state, so recalibrated is false and the section describes the analysis database's calibration. The m/z calibration step still names the state a conversion applied.

mz_standard_deviation_ppm is the square root of the reference peaks' summed squared m/z errors after the calibration, in ppm, over one less than the number of peaks. That is Bruker's MzStandardDeviationPPM, recomputed from the file's own arrays to six decimals on four acquisitions, and PHI's calibrants give the same statistic: refitting their theoretical m/z against the flight times the stated coefficients imply reproduces the coefficients exactly, so each calibrant's measured m/z is its position under the fit and the difference its residual. A value is never written where it has nothing to say. A standard deviation of zero is left unset -- a timsTOF calibrated on two peaks fits both exactly, and the online lock-mass state a MALDI timsTOF writes records 0.000000 against a single reference mass and no measured mass at all -- and so is one over fewer than two peaks. The count stands on its own.

Three things are deliberately not in the section. The first is which calibration a conversion applied: that is a processing step (below). On a timsTOF, Bruker's library turns every index into m/z itself. With --use-recalibrated (the default) it applies the newest state in calibration.sqlite, on TSF and TDF alike; with --no-recalibrated it applies the analysis database's own calibration and none of the states. Measured on one acquisition of each: a DataAnalysis 6.1 recalibration moved every ion of a TSF by +1.3 to +1.7 ppm, and a SCiLS Lab 2027a alignment, written into a TDF as its second state, moved each frame by -2.3 to +0.1 ppm. With --no-recalibrated both read exactly as acquired. lock_mass_corrected stays unset for timsTOF, for two reasons. Whether the m/z carry the online lock-mass correction depends on that option, so it describes a conversion, not the source. And on a TDF the lock-mass state changed no m/z on either of the two acquisitions checked, so what it corrects cannot be read off the file. The mobility calibration's keys are not read: on the one imaging TDF with TIMS engaged its measured voltages are all zero and its standard deviation is 3578 %. And no person reaches the section: CalibrationUser and MobilityCalibrationUser are not read, and neither is the reference list's name, which is text the lab chose.

The alignment section says which optical image the source registers its raster onto, and how. Only flexImaging states one, in the .mis file beside a Bruker acquisition:

Source optical_image_file method teaching_points
Bruker tsf/tdf, rapiflex, solariX, with a .mis <ImageFile>, name only "teaching points" when there are three or more each <TeachPoint>
Everything else -- -- --

The stage positions are in micrometres, in the frame the teaching was done in. The positions the acquisition records its spectra at are offset from that frame, so the points place the image on the target, not on those positions. The .mis Areas stay in raw_metadata: an acquisition can hold fewer of them than the file lists. Whether a conversion placed the raster in the image's pixels is for the store's coordinate_systems attribute to say (see Coordinate Systems).

Everything else -- organism, tissue, condition, matrix -- cannot come from a raw file and stays empty until you provide it.

Processing history

processing is the dataset's processing provenance, modeled on mzQC: an ordered list of steps, each naming the software that performed it and the parameters it ran with, and the PSI-MS data processing action it is (action_term) where one exists. The converter records its own steps -- conversion always, m/z calibration when the reader turned flight times or digitiser indices into m/z with a calibration it chose, and mass axis resampling with the resolved resampling parameters when resampling was enabled. Downstream tools (normalisation, peak picking, annotation) append theirs when they modify the store.

In mass axis resampling, mass_width_da is the bin width at reference_mz. It is the width asked for when that width set the bin count. When a bin count or the 100-bin floor set it instead, it is the width the count gives, and on a tof axis bins_per_fwhm is too. A constant axis lays its count as points, so its step is (max_mz - min_mz) / (n - 1): a recorded width that was asked for is that step up to a factor n / (n - 1). The width law (tof_a, tof_b) is recorded on a tof axis only.

[
  {"name": "conversion",
   "software": {"name": "thyra", "version": "4.1.0"}},
  {"name": "m/z calibration",
   "action_term": {"accession": "MS:1001485", "name": "m/z calibration"},
   "software": {"name": "thyra", "version": "4.1.0"},
   "parameters": {"calibration": "appended"}},
  {"name": "mass axis resampling",
   "software": {"name": "thyra", "version": "4.1.0"},
   "parameters": {"method": "nearest_neighbor", "target_bins": 50000,
                  "reference_mz": 1000.0}}
]

The conversion step's parameters say what the conversion kept:

Parameter When Meaning
tdf_spectrum: "scan_sum" / "vendor_centroid" Bruker tdf how each frame's mobility scans became one spectrum
intensity_threshold: a number --intensity-threshold was given peaks whose summed intensity is below it are not in the store

The m/z calibration step is how a store says which calibration it holds, as distinct from what the source states in calibration: a conversion can be told to apply one the source does not consider current. Its parameters are in the reader's own terms:

Source Parameter Meaning
PHI ToF-SIMS calibration: "appended" / "header" the coefficients Thyra computed m/z from: the recalibration appended to the file whenever there is one, unless the reader's use_appended_calibration was turned off
Bruker tsf/tdf use_recalibrated_state: true / false the option Bruker's library was opened with (--use-recalibrated / --no-recalibrated)
calibration: "calibration.sqlite" / "analysis.tsf" / "analysis.tdf" where the calibration the library applied is stored: the newest calibration.sqlite state with the option on, the analysis database with it off or without that file. Left out when the option is on and calibration.sqlite could not be read
calibration_state_id the Id of the calibration.sqlite state applied, when one was

Other readers take the m/z values the source stores, apply nothing and record no step.

On disk the list is stored as a JSON string (AnnData/zarr cannot round-trip a list of objects -- the same reason uns["regions"] is JSON); read_msi_metadata_blocks and validate_document decode it transparently.


PSI CV alignment

Beyond the per-document *_term values, every schema field that instantiates a PSI CV concept is bound to that concept's accession in the JSON Schema itself (a cv annotation on the field definition), so the claim "Thyra's output is annotated with the same PSI CV terms as the raw file it came from" is machine-checkable from the committed artifact alone:

Field CV concept
ms_analysis.pixel_size_um.x IMS:1000046 pixel size (x)
ms_analysis.pixel_size_um.y IMS:1000047 pixel size y
sample.sample_id MS:1000001 sample number
sample.sample_name MS:1000002 sample name
ms_analysis.polarity MS:1000465 scan polarity
ms_analysis.spectrum_representation MS:1000525 spectrum representation
ms_analysis.ionisation_source MS:1000008 ionization type
ms_analysis.analyzer MS:1000443 mass analyzer type
ms_analysis.instrument_model MS:1000031 instrument model
ms_analysis.manufacturer MS:1001269 instrument vendor
ms_analysis.serial_number MS:1000529 instrument serial number
ms_analysis.detector_resolving_power MS:1000800 mass resolving power
ms_analysis.ion_mobility.separation MS:1002892 ion mobility attribute
ms_analysis.fragmentation.ms_level MS:1000511 ms level
ms_analysis.fragmentation.windows[].target MS:1000827 isolation window target m/z
ms_analysis.fragmentation.windows[].lower_offset MS:1000828 isolation window lower offset
ms_analysis.fragmentation.windows[].upper_offset MS:1000829 isolation window upper offset
ms_analysis.fragmentation.windows[].collision_energy MS:1000045 collision energy
acquisition.laser_frequency_hz IMS:1006000 repetition rate
acquisition.shots_per_pixel IMS:1006001 laser shots per spectrum
alignment.optical_image_file IMS:1006008 optical image location
alignment.method IMS:1006017 method used to align optical image

On the input side, every imzML file-description cvParam is preserved in uns["raw_metadata"]["cvParams"] with its accession (and unit accession where the source set one) -- the name alone cannot be resolved back to the CV concept. The list is stored as a JSON string (see Output Format for why); json.loads hands back the list of terms. Polarity is read from these terms, from the parameter groups and from every spectrum. A file that states both values anywhere records neither. A metadata-only read (thyra metadata, the preview) looks at the first spectrum only.

Candidate CV terms

Several imaging concepts this schema needs have no CV term yet. They are tracked in CANDIDATE_CV_CONCEPTS as the vocabulary to raise in the PSI/mzPeak imaging discussions, so this schema and the future standard converge:

  • pixel size semantics (raster pitch vs laser spot vs binned size)
  • pixel size provenance (measured vs user-supplied vs default)
  • coordinate origin and axis handedness
  • stage offset of the raster origin
  • ROI / acquisition region identity
  • missing / empty pixel semantics
  • continuous-vs-processed source provenance after conversion
  • mass axis resampling provenance (method, axis law, target bins)
  • mass axis identity (a hash of the stored m/z values)
  • acquisition start timestamp (mzML has only the run's startTimeStamp attribute; MS:1000747 is the completion time)
  • laser power as a percentage of the instrument's range (MS:1000846 pulse energy is in joules)
  • acquisition method identity (MS:1002128 names a method file format, not the method)
  • number of spectra of any MS level (MS:4000059 and MS:4000060 count MS1 and MS2 spectra separately)
  • when an m/z calibration was made, whether a recalibration replaced it, and what software made it (MS:1001485 m/z calibration is a processing action with no attributes; MS:1003200 software version is scoped to spectral libraries)
  • an m/z calibration's fit: its residual in ppm and how many reference peaks it rests on (MS:1000014 accuracy is an analyzer attribute, MS:4000072 the error of one identified ion)
  • lock-mass correction of the m/z values
  • a teaching point: a pixel of the optical image paired with the stage position of the same feature (IMS:1006017 names the alignment method, with no term for the points it rests on)

MS:1001485 itself is used, as the action_term of the m/z calibration processing step -- the one place the schema names a calibration as something done rather than something stated.

LinkML rendering

The schema is also rendered as LinkML at thyra/metadata/schema/msi_metadata.linkml.yaml -- classes, slots, required flags, slot_uri CV bindings and the polarity enum with meaning: accessions. The pydantic models remain the source of truth for what Thyra writes and validates; the YAML is the discussion artifact for LinkML-native settings (the PSI/mzPeak imaging work, the planned spec repository), and a unit test keeps the two from drifting. A later migration to LinkML-as-source changes no field names and nothing on disk.


var column conventions

The MSI table's .var column names are fixed by the spec so every consumer can rely on one spelling:

Column Written by Meaning
mz every converter, required The common mass axis. Numeric, finite, strictly increasing -- except on a sibling table, where the pair is what is unique and sorted: (mz, mobility) on a mobility-resolved one, (precursor_mz, precursor_mobility, mz) on a demultiplexed MS/MS one, where precursor_index identifies the block.
mobility the converter, on mobility-resolved tables only The feature's ion mobility (1/K0 or drift time; see uns["mobility_axis"]). Its presence is what marks the table as mobility-resolved.
precursor_mz the converter, on demultiplexed MS/MS tables only The isolated m/z the feature's fragments came from (see uns["msms_schedule"]). Its presence is what marks the table as demultiplexed; such a table never carries mobility as well.
mz_index the converter, on sibling tables only Column of the feature's m/z on the summed MSI table's axis
mobility_index the converter, on mobility-resolved tables only The feature's position on the table's mobility axis: the rank of its mobility among the distinct values a shared-axis source lists, or the channel it fell in on a common grid (ion_mobility.grid)
precursor_mobility the converter, on demultiplexed MS/MS tables only The 1/K0 the precursor was isolated at (the middle of its mobility window). What tells two precursors sharing an m/z apart -- an isomer pair -- so they are never merged
ccs the converter, on mobility-resolved tables whose axis is 1/K0 The feature's collision cross section in square angstroms, computed by Mason-Schamp from its mz and mobility for an assumed charge of 1, in nitrogen at 305 K. uns["ccs"] records those assumptions. A drift-time table has no such column. Any table that carries it must hold numeric, finite, positive values
precursor_index the converter, on demultiplexed MS/MS tables only The precursor's position in this store's precursor axis, and the identity of its column block. Means nothing outside the store: align two stores on (precursor_mz, precursor_mobility)
formula annotation tools Molecular formula of the annotation
adduct annotation tools Adduct, e.g. +H, -H, +Na
annotation_source annotation tools Tool/database that produced the annotation
fdr annotation tools False discovery rate of the annotation

Readers may add extra per-channel columns (a non-m/z native axis such as flight time stays alongside mz), and annotation tools may add columns beyond these -- but the reserved names above must never be reused with a different meaning. thyra validate checks the mz contract on every table of a store, and the ccs contract on every table that has one.

obs column conventions

One .obs name is fixed by the spec as well. The pixel columns beside it (x, y, spatial_x, region_number and the rest) are described in Output Format.

Column Written by Meaning
acquisition_order the converter, when the reader knows the order; absent otherwise int64, grows with acquisition time and is unique within a table. The source's own spectrum number where it has one (Bruker Frames.Id, solariX Spectra.Id), else the spectrum's 0-based position in the order the source lists them. A row summed from repeated measurements takes the earliest. Sort by it; it is not a row index. See Acquisition order

A missing column means the order is unknown. The name must never be reused with a different meaning.


Storage contract

  • The block lives at table.uns["msi_metadata"], in every table the store has. This location is stable, like uns["essential_metadata"] and the coordinate_systems root attribute; consumers read it from here and nowhere else.
  • It is written identically by every converter write path (the uns parity tests assert this), and records no time of the conversion itself -- the acquisition's start time comes from the source -- so converting the same input twice produces the same block.
  • Sections with nothing in them are omitted rather than written empty, following the store-wide convention.

Versioning

schema_version follows semantic-version rules:

  • Adding an optional field bumps the minor version.
  • Renaming, removing, retyping, or making a field required bumps the major version.
  • A validator implementing major version N rejects documents with a different major version, accepts older minors, and warns on newer minors.

Versions so far: 0.1.0 (initial), 0.2.0 (ms_analysis.ion_mobility added), 0.3.0 (ion_mobility.resolved_table and ion_mobility.grid added), 0.4.0 (ms_analysis.fragmentation added), 0.5.0 (fragmentation.resolved_table added), 0.6.0 (the acquisition section added), 0.7.0 (ms_analysis.manufacturer and ms_analysis.serial_number added), 0.8.0 (the calibration section, ms_analysis.n_spectra and the processing steps' action_term added), 0.9.0 (the alignment section added), 0.10.0 (the obs column acquisition_order reserved; the document is unchanged), 0.11.0 (provenance.mass_axis added), 0.12.0 (sample.sample_id, sample.sample_name and ms_analysis.spectrum_representation added), 0.13.0 (the var column ccs reserved; the document is unchanged), 0.14.0 (the coordinate system "acquisition" reserved; the document is unchanged).

The JSON Schema rendering is published at a fixed, versioned address, which is also its $id:

https://M4i-Imaging-Mass-Spectrometry.github.io/thyra/schema/0.14.0/msi_metadata.schema.json

Every version from 0.6.0 on has its own folder under that path, and a published folder is never edited; there is deliberately no latest. The LinkML source of the same version is served beside it as msi_metadata.linkml.yaml. A program that writes the document without Thyra validates against that address; see Writing the Metadata Document.

The same file is committed at thyra/metadata/schema/msi_metadata_schema_v0_14.json and ships in the wheel, so a Python consumer can validate documents offline without importing Thyra:

from importlib import resources
import json

schema = json.loads(
    resources.files("thyra.metadata.schema")
    .joinpath("msi_metadata_schema_v0_14.json")
    .read_text()
)

Unit tests keep the package artifact in sync with the models and the published copy in sync with the package artifact; regenerate both with python -m thyra.metadata.schema.generate after a model change. A version bump creates a new folder under docs/schema/; the previous version's folder stays as it is. docs/schema/SHA256SUMS records the SHA-256 of every published file, and a unit test fails when any of them changes, so regenerating a version that is already published fails the suite instead of rewriting it. The pull request that adds a version folder appends that folder's lines to SHA256SUMS; the failing test prints them.


thyra metadata

thyra metadata INPUT [--merge USER.json] [-o OUT.json]

Builds the same document from a raw source and writes it out, without converting anything. INPUT is a file or folder in any format Thyra reads. For every format but Waters, no spectra are decoded and no vendor SDK is loaded, so it is a header read whatever the dataset's size; a Waters run is described through the MassLynx library, which reads every scan. The default output is stdout.

The document is the one a conversion would have stored, with three differences, and a fourth for PHI data. Two follow from nothing having been converted: processing is absent, and no sibling table is named; for PHI, ms_analysis.n_spectra is absent too, because counting the pixels that carry a spectrum means decoding the whole event stream. The third follows from where the document goes: provenance.source_path is the source's name, where a store block carries the path it was converted from. A store sits on the machine that wrote it and the path is provenance a reader can act on; a document is written to be handed to somebody, and an absolute path describes a filesystem they do not have while carrying a user directory to a machine that has no use for it. Everything else -- the sections, the ontology terms, the JSON shape -- is identical, so a document written this way and the same dataset's block read back out of a store compare directly.

thyra metadata raw_data.d
thyra metadata raw_data.d --merge sample.json -o meta.json

An acquisition with no raster has no pixel size, which this schema version requires, so its document is reported as invalid and the command exits 1 -- while still writing the document, which is the only kind such an acquisition has. See Design Decisions.


thyra validate

thyra validate PATH [--merge USER.json] [--json]

PATH is a converted .zarr store or a standalone metadata .json document. Only the metadata block (and, for stores, the var axis) is read -- validating a 100 GB store is instant. For stores it also checks the var column contract and that every table carries a metadata block. Exit status is 0 when every document conforms (warnings allowed) and 1 otherwise, so it can gate CI.

On Windows, a store whose files sit past the 260-character path limit is read through an extended-length path automatically; without that, Zarr would return empty terms for the keys it cannot open and the document would fail validation for the wrong reason (see long paths).

Errors mean the document does not conform: structural violations, unknown PSI-MS/IMS/UO accessions, version incompatibility. Warnings mean it conforms but says something suspicious: a term label that does not match its accession, or a term from an unexpected ontology.

thyra validate output.zarr
# msi_dataset_z0: OK

thyra validate output.zarr --json   # machine-readable report on stdout

thyra export-metaspace

thyra export-metaspace PATH [--merge USER.json] [--table NAME] [-o OUT.json]

Writes the METASPACE submission metadata JSON (default: <input>.metaspace.json next to the input; -o - for stdout). Required fields the store cannot know are written empty, or left out in the case of Detector_Resolving_Power, and reported as warnings on stderr -- the output is a truthful starting point, never a fabricated record. Two values are filled without being stated: matrix-free sources (DESI, SIMS) get MALDI_Matrix: "none", and an unset solvent is written as "none".

thyra export-metaspace output.zarr
# warning: Sample_Information.Organism is required ... and is not set
# Wrote METASPACE metadata for msi_dataset_z0 to output.metaspace.json

Completing the metadata

The fields only you can know go in a small JSON overlay, merged at validation or export time with --merge:

{
  "sample": {
    "organism": "Mus musculus",
    "organism_term": {"accession": "NCBITaxon:10090", "name": "Mus musculus"},
    "organism_part": "liver",
    "organism_part_term": {"accession": "UBERON:0002107", "name": "liver"},
    "condition": "wildtype"
  },
  "preparation": {
    "sample_stabilisation": "fresh frozen",
    "matrix": "2,5-dihydroxybenzoic acid (DHB)",
    "matrix_term": {"accession": "CHEBI:17189", "name": "2,5-dihydroxybenzoic acid"},
    "matrix_application": "ImagePrep"
  },
  "ms_analysis": {
    "detector_resolving_power": {"value": 130000, "at_mz": 400}
  }
}
thyra validate output.zarr --merge sample.json
thyra export-metaspace output.zarr --merge sample.json

The overlay merges key-by-key over the stored block, so it only needs the fields you are adding. Keep it next to the store; it applies unchanged to every dataset from the same study. Name each sample at conversion instead (--sample-id, or sample_id and sample_name in convert_msi): that name is stored, so it tells stores of one study apart. One conversion names one sample, even when the slide holds several regions.

Python API

from thyra.metadata.schema import (
    MSIMetadata,             # the pydantic model
    read_msi_metadata_blocks,  # {table_name: block} from a store
    validate_document,       # (model | None, issues)
    to_metaspace,            # (submission_dict, warnings)
)

blocks = read_msi_metadata_blocks("output.zarr")
meta, issues = validate_document(blocks["msi_dataset_z0"])
submission, warnings = to_metaspace(meta)